Error codes for air conditioners Beko (Beko, Beko) - decoding and instructions

Troubleshooting

Having detected a malfunction in the operation of any units, the device displays an error code on the display. If the problem is serious, the air conditioner will usually stop working. If more than one breakdown is detected at the same time, the most serious one is displayed on the board.

Error codes of VECO air conditioners of BKL INV and BKC INV types

VECO air conditioner error codeDecoding
E1Malfunction of the temperature sensor of the indoor module
E2 errors of air conditioners VekoMalfunction of the evaporator temperature sensor
E3Compressor malfunction
E5No communication between outdoor and indoor units
1E errors of air conditioners VekoViolation of the outside air temperature sensor
2EFailure of the condenser temperature sensor

Error codes for VECO air conditioners of types AKH, BKH, AKP, BS, BKP, AS

VECO air conditioner errorDecoding
FF03Condenser overheating, option "cold"
FF04 Beko air conditioner error codeCondenser overheating, heat option
FF06Indoor unit fan function failure
FF07Failure of the room temperature sensor
FF08 Beko air conditioner error codeEvaporator temperature sensor malfunctioning
FF09Condenser temperature sensor malfunctioning

Error codes for VECO air conditioners of types BKN and AKN

Beko air conditioner error RANNING indicatorSLEEPING indicatorTIMER indicator
Failure of function of the temperature sensor of the solenoid type insideBlinkingBlinkingBlinking
Failure of the room temperature sensor functionBlinkingBlinkingShines without interruption
Failure of function of the temperature sensor of solenoid type outsideBlinkingBlinkingDisabled
Indoor unit fan motor function failureblinksShines without interruptionBlinking

Any of the above air conditioner errors Beko is the reason for the immediate shutdown of the device.

Error codes for air conditioners Beko (Beko, Beko) - decoding and instructionsThe most common malfunctions in the operation of air conditioners and the reaction of the system to their occurrence:

  • The secondary activation of the compressor is delayed by 3 minutes;
  • If the compressor top temperature is more than 115 degrees, it stops working. The normal operating temperature is one hundred degrees;
  • If the voltage level in the network is less than 175 or more than 260 volts, the equipment is turned off;
  • If the inverter overheats, too much current or high voltage is supplied to it, the system will shut it down;
  • If the electrical wires are disconnected in any of the units, the air conditioner stops;
  • If the fan works weaker or more intensively than the norm (the norm is 300 - 400 rpm), the air conditioner is turned off;
  • If within four minutes the system does not receive messages about crossing the "0", it is switched off.