When a breakdown is detected by the system, error codes of Bork air conditioners are displayed on the front panel of the outdoor unit. The codes are combinations of flashing and illuminated multi-colored LEDs.
Decoding the error of air conditioners Bork | Error code air conditioner Bork Diode 1 | Diode 2 | Diode 3 |
Air conditioner error Bork Violation of the rise and fall of pressure | blinks | blinks | Blinking |
Cooling refrigerant in warm mode | — | Lights up | Lights up |
Excess compressor temperature | Lights up | — | Lights up |
System voltage too low | — | Lights up | — |
Bork air conditioner error: engine speed is corrected | Lights up | Lights up | Lights up |
Outdoor unit overload protection is enabled | — | Lights up | Blinking |
If the compressor does not turn on, the LEDs of the outdoor unit show the following error codes for Bork air conditioners
Decoding the error of the air conditioner Bork | Diode 1 | Diode 2 | Diode 3 |
Works fine | — | — | — |
Short circuit on the room temperature sensor | — | — | Lights up |
Short circuit of the temperature sensor of the internal heat exchanger | — | Lights up | — |
Errors of air conditioners Bork: Short circuit of the compressor temperature sensor | Lights up | — | — |
The function of the temperature sensor of the external heat exchanger is broken | Lights up | — | Lights up |
The function of the outside air temperature sensor is broken | Lights up | Lights up | — |
Power supply interrupted | Blinking | Lights up | — |
The power supply to the outdoor unit is interrupted | Blinking | — | Lights up |
No communication between indoor and outdoor units | — | — | Blinking |
Overvoltage protection enabled | — | Blinking | — |
Errors of air conditioners Bork: Maximum current control | Lights up | Blinking | Lights up |
Equipment shutdown due to overload | Lights up | Blinking | — |
Compressor temperature exceeded | — | Blinking | Lights up |
Indoor and outdoor unit current monitoring has shut down the system | Lights up | Lights up | Blinking |
Ambient air temperature higher or lower than planned by the manufacturer | Lights up | Blinking | Blinking |
Refrigerant leak | Blinking | Lights up | Lights up |
Compressor overheating | — | Lights up | Blinking |
Incorrect operation of the outdoor unit | Lights up | Lights up | Lights up |
Incorrect operation of the engine of the indoor unit | — | Blinking | Blinking |
Violated communication with the control board | — | Lights up | Lights up |
The compressor has stopped due to an error | Blinking | — | Blinking |
Fan breakage | Blinking | Blinking | Lights up |
Outdoor compressor overheated | Lights up | Blinking | Lights up |
In order to start the self-diagnosis function, press the POWER button four times in ten seconds and the error codes of the Bork air conditioner will be displayed on the display.