The latest generation Daikin air conditioners contain both mechanical and electronic modules. When there is a problem with the system, it is very difficult to diagnose the problem. Therefore, the equipment is equipped with a self-diagnosis function that detects a failure and notifies the user about it.
Error codes are displayed on the control panel display. If the equipment is operating in abnormal mode, an alphanumeric code blinks on the monitor.
Daikin air conditioner error codes
Deciphering the error of the Daikin air conditioner | ||
Literal meaning | Digital value | |
BUT | 0 | Equipment breakdown prevention |
BUT | 1 | Indoor module board failure |
BUT | 2 | Fan motor does not work |
BUT | 3 | The amount of condensate in the collection container has been increased |
And the air conditioner error Daikin | 4 | Broken heat exchanger |
BUT | 5 | Too high or low temperature of the heat exchanger |
BUT | 6 | Fan motor overheating |
BUT | 7 | No power supply to the blinds |
BUT | 8 | Overvoltage in the network |
A | 9 | Broken expansion valve board |
AA | Heating element temperature exceeded | |
AH error of the Daikin air conditioner | Filters need to be cleaned | |
AC | No cooling / heating | |
AJ | Indoor module control function broken | |
AE | There is not enough water in the installation | |
AF | The humidification function is impaired | |
C | 0 | The function of the temperature sensor is broken |
C | 3 | The function of the sensor measuring the amount of condensate in the tank is broken |
C | 4 | Internal heat exchanger temperature sensor failure |
C | 5 | Failure of the temperature sensor of the external heat exchanger |
C | 6 | The sensor has stopped the fan due to overheating of the motor |
C | 7 | Breakage of the blinds movement sensor |
C | 8 | No control over incoming mains voltage |
C | 9 | Broken input thermistor |
CA | Broken output thermistor | |
CH error code Daikin air conditioner | You should clean the indoor unit from dust | |
CC | Broken sensor that detects humidity inside the air conditioner | |
CJ | Breakdown of the temperature sensor on the remote control | |
CE | There is no communication between the remote control and the indoor unit | |
CF | High pressure sensor breakage |
Outdoor unit error codes
Deciphering the error codes of the Daikin air conditioner | ||
Literal meaning | Digital value | |
E | 0 | The unit is disabled due to an accident |
E | 1 | No communication with the head PCB of the outdoor unit |
E | 3 | System pressure too high |
E | 4 | System pressure too low |
E | 5 | Compressor off due to overtemperature |
E error code Daikin air conditioner | 6 | The compressor is disconnected due to overvoltage in the mains |
E | 7 | The fan motor is stopped due to overvoltage in the network |
E | 8 | Too high voltage applied |
E | 9 | Expansion valve malfunctioning |
EH | Pump stopped | |
EC | The water temperature is too low or high | |
EJ | Additional protection of the block has turned on | |
EE | Increased amount of condensate | |
EF | Broken heating module | |
H | 0 | Broken temperature sensor |
H | 1 | Breakdown of the outdoor temperature sensor |
H | 2 | Electricity supply interrupted |
H | 3 | The pressure in the system is increased |
H | 4 | System pressure lowered |
H | 5 | Compressor shutdown due to overload |
H | 6 | The fan is off due to motor overload |
H | 7 | Disturbed input voltage distribution |
H | 8 | The outside temperature is too low or too high |