Having carefully studied the error codes of General Fujitsu air conditioners on the display, each user can eliminate minor problems without the help of a specialist.
If the air conditioner error code is displayed on the control panel General fujitsu EE, you must simultaneously press and hold for at least three seconds the "energy saving" and "mode change" buttons. The monitor will display error codes:
stop equipment operation;
- General Fujitsu air conditioner error scanning is started by simultaneously pressing the "master control" and "fan" buttons for two seconds;
- to stop scanning, press the start button.
Content
Self-diagnosis mode
If E is displayed on the remote control, it is necessary to carry out self-diagnosis of errors of General Fujitsu air conditioners.
It is necessary to stop the operation of the equipment, press the "temperature" button and hold it for 5 seconds. Self-diagnosis has started.
General fujitsu air conditioner error codes
Error code | What does |
00 | There is no communication between the indoor unit and the control panel |
01 | No communication between indoor and outdoor units |
02 | The operation of the temperature sensor that measures the temperature in the room is broken |
03 | Indoor module temperature sensor short circuit |
04 | The temperature sensor of the indoor module is disconnected |
05 | Failure of the temperature sensor of the indoor module |
06 | No external heat exchanger connection |
07 | Short circuit of the external heat exchanger sensor |
08 | Not enough power |
09 | Condensate container full |
0A | No contact with the temperature sensor of the outdoor unit |
0V | Short circuit on the temperature sensor of the outdoor unit |
0C | Thermal sensor does not function |
0D | Short circuit on the temperature sensor tube |
0E | Too high pressure |
0F | Breakage on the temperature tube |
11 | No communication with compressor |
12 | Indoor unit fan broken |
13 | Main board does not respond |
14 | No communication with the room temperature sensor. |
General fujitsu air conditioner error indication
What does the General fujitsu air conditioner error mean? | Indication | |||
OPERATION | TIMER | AIR CLEAN or QUIET | ||
Lost connection | Between outdoor and indoor unit | — | 2-3 flashes | — |
Indoor unit temperature abnormality | The temperature sensor does not work correctly in the room | 2 flashes | 2 flashes | — |
The heat exchanger temperature sensor does not work correctly | 2 flashes | 3 flashes | — | |
Outdoor unit temperature abnormality | The temperature sensor of the discharge pipe does not work correctly | 3 flashes | 2 flashes | — |
The heat exchanger temperature sensor does not work correctly | 3 flashes | 3 flashes | — | |
The operation of the external temperature sensor is incorrect | 3 flashes | 4 flashes | — | |
Two-way valve thermistor failure | 3 flashes | — | 2 flashes | |
Three-way valve thermistor failure | 3 flashes | — | 3 flashes | |
Radiator temperature sensor | 3 flashes | 7 flashes | — | |
Compressor temperature sensor | 3 flashes | 8 flashes | — | |
Indoor unit monitoring system failure | Button Broken Manual auto | 4 flashes | 2 flashes | — |