KSRU \ KSFU series error codes
Air conditioner error codes Kentatsu for models: KSRU70HFAN1, KSFU70XFAN1, KSFU120XFAN3, KSRU120HFAN3
Kentatsu air conditioner error | Decoding errors |
E1 | No contact with the air temperature sensor in the indoor unit |
E2 | No contact with the evaporator temperature sensor |
E3 | No contact with condenser temperature sensor |
E4 | No contact with the outdoor air temperature sensor |
E5 | No contact between outdoor and indoor units |
E6 | Outdoor unit overheat / frost prevention |
E10 | Compressor pressure failure |
E13 | The wires supplying electricity to the compressor are reversed |
E14 | Electricity is supplied to the wrong phase |
P4 | Evaporator overheating warning |
P5 | Condenser overheating prevention |
P7 | The compressor is turned off in automatic mode, due to the temperature rise to the limit level |
P9 | Frost protection on equipment |
P10 | Incorrect outlet air pressure |
P11 | Air is sucked in at a pressure not specified by the manufacturer |
P12 | Too high voltage is supplied to the air conditioner |
HS | Defrosting the outdoor unit |
KSGH \ KSRH series error codes
Error codes for models KSGH / KSRH53CFDN1, KSGH / KSRH21CFDN1, KSGH / KSRH53HFDN1, KSGH / KSRH35HFDN1, KSGH / KSRH26CFDN1.
Kentatsu air conditioner error code | Decoding the error |
E1 | EERPOM crash |
E2 | Zero Cycle Transformation Failure |
E3 | Fan turns too fast or too slow |
E4 | Compressor off due to too high voltage supply |
E5 | Lost communication with air temperature sensor inside |
E6 | Lost Communication With Evaporator Thermal Sensor |
Kentatsu air conditioner error code for KSFU / KSRU140HFDN3 and KSFU / KSRU76HFDN3 models
Kentatsu air conditioner error | Decoding errors of air conditioners Kentatsu |
P4 | Overheating protection of the evaporator located in the indoor module |
P5 | Outdoor unit condenser overheating protection |
P9 | Thawing |
E1 | The voltage is not supplied to the temperature sensors |
E2 | No communication with the evaporator temperature sensor |
E3 | No contact with condenser temperature sensor |
E6 | Outdoor unit breakage prevention |
Error codes for duct type air conditioners
Errors | Decoding |
E0 | Breakdown of the room temperature sensor |
E1 | Evaporator temperature sensor breakage |
E2 | Breakdown of the temperature sensor of the outdoor unit |
E3 | No communication with outdoor unit |
E4 | Damage to the condensate drain pump |
E5 | EEPROM failure |
E6 | The condensate drain pan is full |
error E9 can't find the reason
Hello Oleg!
And which model are you specifically interested in? Different designations are everywhere.
Best regards, Valery.
Hello, the multisplit air conditioner writes an error e1 on the indoor unit, model KMGC35, I cannot find a list of errors on this unit, what could it be? Thank you.
Alexander, as a rule, all e1 errors are connected in one way or another with a thermal sensor. Do you want to launch it now? it is still frosty outside, and the air conditioners are not designed for this without a winter kit. The problem may lie in this.
Error F0 was displayed on the newly installed Kentatsu cassette air conditioner. What does it mean?? All icons on the panel of the indoor unit are blinking.