Error codes for air conditioners Pioneer (Pioneer) - transcript and instructions

Error codes for air conditioners Pioneer (Pioneer) - transcript and instructionsTo detect malfunctions in the Pioneer air conditioner system, there is a self-diagnosis function. Error codes for Pioneer air conditioners are displayed using various combinations of multi-colored LEDs located on the front panel of the indoor unit. If the system detects several faults at the same time, the codes are shown in turn.

Air conditioner errors Indoor unit pioneer

Air conditioner error code PioneerYellow diodeGreen diode

Red diode

Pioneer air conditioner error decoding
E0*The function of the discharge temperature sensor is broken
E6*The function of the condenser temperature sensor is broken
E6*The function of the outdoor air temperature sensor is broken
E1*The function of the temperature sensor in the room is broken
E2*The function of the evaporator temperature sensor is broken
E3mmmIndoor unit fan broken
E4m*IPM system failure
E5mmPower outage
E8*mmViolation of voltage supply
E9mThe compressor did not start correctly
EA*Incorrect communication with the outdoor unit
The EUm*The air conditioner is supplied with an electrical current of unacceptable parameters
HEREEPROM failure
EPNo communication between outdoor and indoor modules
P0Unit started incorrectly
Р1Discharge overheating
P2Increased current in the circuit
P3Mains voltage too high
P4mm*No communication with the current relay
P5Evaporator overheating
P6Overheating of the condenser
P7IPM Matrix Protection

*- the diode is on, m - the diode blinks.

Outdoor unit Pioneer air conditioner error codes

The outdoor unit has a red LED, which normally blinks like this: once from the ON side, once from the OFF side. If a malfunction is detected, the diode blinks twice on the OFF side and three times on the ON side.

After that, the frequency of blinking increases, and their mode will correspond to the error code of the Pioneer air conditioner.

Pioneer air conditioner error code (number of diode blinks)Decoding the air conditioner error Pioneer
1No communication with the external temperature sensor
2No communication with the condenser temperature sensor
3No communication with the discharge temperature sensor
4The current in the mains is too high
5Mains voltage too high
7No communication with indoor unit
9The unit has not been started up correctly
12Mains voltage exceeded
13IPM board protection
16Excess compressor temperature
17Discharge temperature is too high
18Condenser temperature too high
19Failure of the IPM card
20Indoor and outdoor communication failure
22De-icing