Error codes for air conditioners Toshiba (Toshiba) - transcript and instructions

Air conditioner error codes Toshibadisplayed on the display of the indoor module.

Letter designation starts with E

Toshiba air conditioner error codeToshiba air conditioner error code decoding
Letter meaning of Toshiba air conditioner error codesDigital meaning of Toshiba air conditioner error codes
E01No communication between indoor unit and remote controller
E02Invalid data coming from the remote control
E03No communication between indoor unit and remote controller
E04 Toshiba air conditioner error codeNo communication between outdoor and indoor units
E06Electric current does not flow to the indoor module, the board is likely to break, the contact between the modules is broken
E07Broken temperature sensor SW30-2
E08Module addresses are not transmitted correctly
E09Broken remote control
E10The board of the indoor module is broken
E12 Toshiba air conditioner mistakesData is not transferred correctly in an external module
E15The function of the indoor module board is broken, the electric current is not supplied correctly
E16Broken outdoor unit PCB
E18No batteries are inserted in the remote control or the board of the indoor module is broken
E19Broken board or no contact between modules
E20The prescription of the address in the settings is violated
E23Incorrectly connected pipeline for freon
E25No external module address
E26No contact with external module
E28 Toshiba air conditioner error codesExternal modules are not connected correctly
E31Information on the boards of the external module does not pass correctly, breakdown of boards

Letter designation starts with F, H, L

The literal meaning of the error codeNumerical value of the error codeDecoding the error code
F01Broken TCJ sensor
F02TC2 sensor not connected correctly
F03TC1 sensor is not connected correctly
F04TD1 sensor not connected correctly
F05Sensor TD 2 does not work correctly
F06Sensor TE1 does not work correctly
F07TL sensor does not work correctly
F08The TO sensor does not work correctly
F10The TA sensor does not work correctly
F12Sensor TC 1 does not work correctly
F13IGBT power module malfunction
F15Malfunction of TL, TE sensors
F16The function of the resistance sensors Ps, Pd is broken
F23The function of the sensors Ps, Pd, 4-way valve is broken
F24The high pressure sensor does not work correctly
F29EEPROM failure
F31Electricity supply failure
H01The device is supplied with voltage that is not permissible
H02Phase connection interrupted
H03The work of the energy sensor is broken
H04Compressor malfunctioning, insufficient refrigerant
H06Inadmissible pressure in the system
H07Lack of oil in the system
H08Oil temperature increased
H14Compressor failure
H16Short circuit on the oil sensor
L03The address of the external module is not correctly registered
L04Addresses are spelled incorrectly